AC A 
									(50/60Hz) | 
									200mA/2/20/200A/1000A 
									|±1.5%rdg±2dgt (200mA/2/20A) 
									|±2%rdg±2dgt (200A 0~500A) 
									|±5.5%rdg (501~1000A) | 
								
								
									AC A 
									(WIDE) | 
									200mA/2/20/200/1000A 
									|±1%rdg±2dgt [50/60Hz], 
									|±3%rdg±2dgt [40Hz~1kHz] (200mA/2/20A) 
									|±1.5%rdg±2dgt [50/60Hz], 
									|±3.5%rdg±2dgt [40Hz~1kHz] (200A/0~500A) 
									|±5%rdg [50/60Hz], 
									|±10%rdg [40Hz~1kHz] (501~1000A) | 
								
								
									| Conductor Size | 
									Ø68mm max. | 
								
								
									Effect of External 
									Stray Magnetic Field 
									Ø15mm 100A | 
									10mA AC max. | 
								
								
									| Frequency Response | 
									40Hz~1kHz | 
								
								
									| Output | 
									
									
										
											
												| Waveform : | 
												AC200mV against the maximum value of each range (1000A range is 100mV) | 
											 
											
												| Recorder : | 
												DC200mV against the maximum value of each range (1000A range is 100mV) | 
											 
										
									 
									 | 
								
								
									| Withstand Voltage | 
									3700V AC for 1 minute | 
								
								
									| Applicable Standard | 
									IEC 61010-1 CAT.III 300V 
									IEC 61010-2-032 | 
								
								
									| Power Source | 
									6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours | 
								
								
									| Dimensions | 
									250(L) × 130(W) × 50(D)mm | 
								
								
									| Weight | 
									570g approx. | 
								
								
									| Accessories | 
									9094 (Carrying Case) 
									6F22 × 1 
									Instruction Manual | 
								
								
									| Optional | 
									7073 (2WAY Output Cord) |