AC A |
400.0/2000A |
|
|
±1.3%rdg±3dgt |
(0~400.0A, 150~1700A) |
(45~66Hz) |
|
±2.0%rdg±5dgt |
(0~400.0A, 150~1700A) |
(20Hz~1kHz) |
|
±2.3%rdg±3dgt |
(1701~2000A) |
(45~66Hz) |
|
DC A |
400.0/2000A±1.3%rdg±2dgt |
AC V |
40.00/400.0/750V |
|
|
±1.0%rdg±3dgt |
(45~66Hz) |
|
±1.5%rdg±5dgt |
(20Hz~1kHz) |
|
DC V |
40.00/400.0/1000V±1.0%rdg±2dgt |
Ω |
400.0/4000Ω|±1.5%rdg±2dgt
(Electronic protection (no fuse) up to 600V) |
Continuity buzzer |
Buzzer sounds below 20Ω |
Hz |
10.0 ~ 4000Hz±1.5%rdg±5dgt
(Input sensitivityCurrent: more than 40AVoltage: more than 10V) |
Output |
Recorder : |
DC400mV against AC/DC400.0A |
|
DC200mV against AC/DC2000A |
|
Withstand voltage |
6880V AC for 5 seconds |
Conductor size |
Ø55mm max. |
Applicable standards |
IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1 |
Power Source |
R6P (1.5V) × 2 |
Dimensions |
250(L) × 105(W) × 49(D)mm |
Weight |
Approx. 540g (including batteries) |
Accessories |
7107A (Test leads), 8201 (Output plug), 9094 (Carrying case)
R6P (AA) (1.5V) × 2, Instruction Manual |
Optional |
8008 (Multi-Tran) (AC only), 7256 (Output cord) |