High sensitivity, miniature AC/DC clamp meter. |
• |
0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current. |
• |
Output terminal for recorder connection. |
Never make current measurement on a circuit above 60V AC/DC
as the instrument is designed for use on low voltage circuits only.
|
|
AC A |
200mA/2/20A
|±1%rdg±2dgt [50/60Hz] (200mA)
|±1.5%rdg±4dgt [40Hz~2kHz] (200mA)
|±1%rdg±2dgt [50/60Hz] (2A)
|±2.5%rdg±5dgt [40Hz~2kHz] (2/20A) |
DC A |
2/20A
|±1%rdg±2dgt (2A)
|±1.5%rdg±4dgt (20A) |
Output |
Recorder : |
DC200mV against AC200mA/2/20A |
|
DC200mV against DC2/20A |
|
Conductor Size |
Ø7.5mm max. |
Frequency Response |
DC, 40Hz~2kHz |
Withstand Voltage |
750V AC for 1 minute |
Power Source |
6LF22(9V) × 1 or AC Adaptor |
Dimensions |
142(L) × 64(W) × 26(D)mm
153(L) × 23(W) × 18(D)mm
Clamp Sensor |
Weight |
220g approx. |
Accessories |
9071 (Carrying Case)
Alkaline 6LF22 × 1
Instruction Manual |
Optional |
8022 (AC Adaptor) (110V)
8023 (AC Adaptor) (220V)
7256 (Output cord) |
|
|