3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage. |
|
Power Quality analysis
(only on KEW 5020)
(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions) |
|
Large Capacity for storing 60,000 data points |
|
60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded |
|
Lowpass Filter will filter out the harmonics
(Cutoff Frequency = Approx. 160Hz) |
|
LED flickers when the preset current / voltage value is exceeded |
|
CALL: Confirmation of recorded data |
• |
The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes) |
• |
RECALL: The last 10 recorded data points including time/date can be recalled on the logger display |
|
Selection of One-time mode or Endless mode |
• |
One-time on: Recording will stop when memory is used up |
• |
One-time off: Overwrite the old data, and store the latest data |
|
Non Volatile Memory |
|
Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years) |
|
Battery power indicator |
|
Indicates battery voltage in 4-levels
(It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing) |
|
The userfriendly PC software "KEW LOG Soft 2" is supplied |
• |
Supplied with the user friendly software "KEW LOG Soft 2". This permits editing, analysis and graphical display of data. |
• |
The recorded data is downloadable onto a PC via USB cable. |
• |
Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor. (only on KEW 5020) |
• |
Simplified Power Integration
(The "KEW LOG Soft 2" uses current and voltage recorded to calculate the integral power consumption) |
• |
Continuous measuring time: Approx. 10 days (Alkaline Battery) |
|
|
Normal Recording Mode
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1) |
|
Range |
RMS Accuracy |
100.0mA |
|±2.0%rdg±0.9%f.s.+ Accuracy of Sensor |
Other ranges |
|±1.5%rdg±0.7%f.s.+ Accuracy of Sensor |
Crest Factor |
|2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s. |
|
*Max, Min and Instant Peak values in Normal Recording mode are just reference values:
their accuracies aren't guaranteed.
Trigger Recording Mode (AC 50/60Hz sine wave)
Range |
Accuracy |
100.0mA |
|±3.5%rdg±2.2%f.s.+ Accuracy of Sensor |
Other ranges |
|±3.0%rdg±2.0%f.s.+ Accuracy of Sensor |
|
Capture/Power Quality Analysis Recording Mode
Range |
Accuracy |
100.0mA |
|±3.0%rdg±1.7%f.s.+ Accuracy of Sensor |
Other ranges |
|±2.5%rdg±1.5%f.s.+ Accuracy of Sensor |
|
|
** Please check specifications under below link:-
Product Catalogue