KM 2060BT

  • KM 2060BT

KM 2060BT

    • S$1,199.00 

      S$930.86

       (Ex Tax: S$854.00)
  • Availability: In Stock

Clamp Power Meter

KEW 2060BT

NEW
KEW 2060BT
KEW CONNECT
 
CE
Extremely large jaw with tear drop shape:
ideal solution for busbar and large currents!
・Conductor size φ75mm and busbar of 80×30mm or less
・Current up to 1000A rms
・Voltage up to 1000V rms
・Harmonics up to 30th
・Various measurement functions: current, voltage, power, harmonics
   and phase detection
・LCD can display simultaneously the values of voltage and frequency
   or power and power factor
・Each degree of harmonics can be shown on the LCD of the tester
・BluetoothⓇ communication functions
 
  • CAT4 600V
  • TRUE RMS
  • Φ75
  • Backlight
  • Bluetooth
2.Power measurement

Power measurement on any wiring system is possible.

KEW 2060BT can perform Single-phase 2-Wire / Single-phase 3-Wire
and balance and unbalance measurements of Three-phase 3-Wire
/ Three-phase 4 Wire. The double display can simultaneously
show many parameters like W & PF, W & deg, W & VA, W & Var,
V & A, etc.

Various parameters such as
active/reactive/apparent power,
power factor, phase differences
(1P2W only) which are required for the power measurement can be
measured.

Total 3-phase power can be
measured in simple steps.

 

By setting the CT and VT ratio and
measuring the secondary side of
the transformation, the primary
side value can be obtained.

 

 

3.Harmonics measurement

Harmonics of the voltage and current, which cause various failures at the field, can be measured.
It is possible to measure and show each voltage and current harmonics up to 30th.
Total harmonics distortion factor is in two types of THD-R and THD-F. Each degree of harmonics can be
shown on the LCD of the tester. Both the current value (or voltage value) and the content ratio can be displayed on the same screen.

4.Phase detection

5.Connectivity

○Dedicated Application "KEW Power*" supports both Android™ and iOS.
○LCD display can be checked at the smart devices.
○Measured values and graphs can be stored with a press of a button.
○Voltage and current can be shown in the waveform display. Existence of the harmonics can be found
  easy.
○Threshhold of each measured value can be set at the applicaion, and PASS and FAIL judgement is
  possible.

 Measurement Data Monitoring Application "KEW Power*"

Please search "KEW Power*"
Communication charge may be incurred separately to download application.

  

  • Application for iOS
    Free iOS software "KEW Power" is available on "APP Store"
    Supporting iOS 10.0
  • Application for Android
    Free Android software "KEW Power" is available on "Google Play Store"
    Supporting Android ver.5.0

 

Wiring connections 1P2W, 1P3W, 3P3W, 3P4W
Measurements and
parameters
Voltage, Current, Frequency, Active power, Reactive power,
Apparent power, Power factor(cosθ), Phase angle,
Harmonics(THD-R/THD-F), Phase rotation
ACV
 
Range 1000V
Accuracy ±0.7%rdg±3dgt (40.0 - 70.0Hz)
±0.3%rdg±5dgt (70.1 - 1KHz)
Crest factor 1.7 or less
ACA
 
Range 40.00/400.0/1000A (3 range auto)
Accuracy ±1.0%rdg±3dgt (40.0 - 70.0Hz)
±2.0%rdg±5dgt (70.1 - 1kHz)
Crest factor 3 or less on 40.00A/400.0A range,
3 or less 1500A peak on 1000A range
Frequency
 
Display Range 40.0 - 999.9Hz
Accuracy ±0.3%rdg±3dgt
Active power
 
Range 40.00/400.0/1000kW
Accuracy ±1.7%rdg±5dgt (PF1, sine wave, 45 - 65Hz)
Apparent power
 
Range 40.00/400.0/1000kVA
Accuracy ±1dgt against each calculated value 
Sum: add errors of each channel, 3P3W: ±2dgt, 3P4W:±3dgt
Reactive power
 
Range 40.00/400.0/1000kVar
Accuracy ±1dgt against each calculated value 
Sum: add errors of each channel, 3P3W: ±2dgt, 3P4W:±3dgt
Power factor
 
Display Range -1.000 - 0.000 - +1.000
Accuracy ±1dgt against each calculated value 
Sum: add errors of each channel, 3P3W: ±2dgt, 3P4W:±3dgt
Phase angle (1P2W only)
 
Display Range -180.0 - 0.0 - +179.9
Accuracy ±3.0°
Harmonics RMS(Content rate)
 
Analysis order 1st - 30th order
Accuracy ±5.0%rdg ± 10dgt (1 - 10th)
±10%rdg ± 10dgt (11 - 20th)
±20%rdg ± 10dgt (21 - 30th)
Total harmonics THD-R/THD-F 
 
Display Range&