Max. input voltage |
|AC 600Vrms, 848.4Vpeak |
Input method |
|Differential input |
Output voltage |
|AC 0~600mV (output/input: 1mV/V) |
Measurement range |
|6~600V |
Accuracy
(Frequency range) |
|±0.5%rdg±0.1mV (50/60Hz) |
Operating Temperature and Humidity Ranges |
|0~40ºC, less than 85% RH (no condensation) |
Input impedance |
|Approx. 3.2MΩ |
Output impedance |
|Approx. 1kΩ |
Environment condition |
|Altitude up to 2000m in indoor |
Applicable standards |
|IEC/EN 61010-1:2001 Measurement CAT.III 600V, pollution degree 2
|IEC/EN 61010-031:2002, IEC 61326:2001 (EMC standard) |
Withstand voltage |
|AC 5350V (actual value 50/60Hz) / for 5 seconds interval
|measurement terminal and exterior main body |
External dimensions/mass |
|87(L)×26(W)×17(D)mm (protrusions omit) /
|Approx. 135g |
Length |
|Approximately 2m |
Output terminal |
|MINI DIN 6PIN |
Accompanying items |
|Instruction manual |
Option |
|7197 (Small safety clip) |